ATAG XL110 107.9kW Commercial Condensing Gas Boiler

€2,835.00

The ATAG XL110 Commercial Condensing Gas Boiler is a high-output modulating boiler designed for large buildings and demanding central-heating installations. It has a nominal gross heat input of 107.9kW and useful heating output of up to 95kW at 80°C/60°C or 102.3kW at 50°C/30°C. Features include an integral modulating pump, modulating gas valve, boiler controls and cascade-system capability. Up to eight XL boilers can be combined in a suitably designed cascade. A correctly sized low-velocity header is required for single and cascade installations.

Fuel Supplier Europe9 Items sold in last 24 hours
17 People watching this product now!

ATAG XL110 107.9kW Commercial Condensing Gas Boiler

ATAG XL110 commercial boiler

The ATAG XL110 Commercial Gas Boiler is a high-output, modulating condensing boiler designed for large buildings and demanding central-heating installations. Part of the ATAG XL Commercial range, it is intended for commercial plant rooms and modular heating systems where substantial heat output is required.

The XL110 has a nominal gross heat input of 107.9kW and useful heating output of up to 95kW at 80°C/60°C or 102.3kW at 50°C/30°C. These ratings distinguish the gas energy entering the boiler from the heat delivered to the heating system.

The ATAG XL Commercial range includes the XL70, XL110 and XL140. These boilers can be installed individually or configured into suitable cascade systems to meet larger heating demands.

Key Features of the ATAG XL110 Boiler

  • ATAG XL110 high-output commercial gas boiler
  • 107.9kW nominal gross heat input
  • Up to 95kW useful heating output at 80°C/60°C
  • Up to 102.3kW useful heating output at 50°C/30°C
  • Modulating condensing central-heating technology
  • Stainless-steel heat-exchanger configuration
  • Integral modulating circulation pump
  • Modulating gas valve
  • Integral boiler controller
  • Electronic MMI cascade controller
  • Automatic air vent
  • Integrated electrical connection rail
  • Compatible manufacturer-approved flue arrangements
  • Wall-mounted or free-standing cascade configurations
  • Cascade capability of up to eight boilers with correctly designed system components
  • Designed for large commercial heating applications

Confirm the exact model configuration, fuel specification, supplied accessories and installation requirements before ordering.

ATAG XL110 Heating Output and Performance

The XL110 has a nominal gross heat input of 107.9kW. Its useful heating capacity depends on the flow and return temperatures of the system.

Technical rating Output
Nominal gross heat input 107.9kW
Nominal net heat input 97.3kW
Useful output at 80°C flow / 60°C return 95kW
Useful output at 50°C flow / 30°C return 102.3kW
Modulating range at 80°C/60°C 14.8–95kW
Modulating range at 50°C/30°C 16.8–102.3kW

These are manufacturer-published figures for the natural-gas XL110. The appropriate operating capacity depends on system temperatures, heating demand and the final installation design.

When comparing commercial boilers, distinguish the nominal heat-input rating from useful output at the required flow and return temperatures.

Condensing Technology

The ATAG XL110 uses condensing technology to recover heat from combustion gases. ATAG publishes efficiency figures under specified operating conditions, including approximately 97.6% at 80°C/60°C and 110.3% at 50°C/30°C, calculated on the net calorific-value basis.

Efficiency figures above 100% can occur when the manufacturer’s calculation uses the lower heating value of the fuel. These figures should not be compared directly with percentages calculated on a different basis.

Actual operating performance depends on system temperature, gas supply, installation quality, commissioning, control settings and maintenance. Published efficiency figures do not guarantee a particular reduction in energy costs.

Integral Pump and Boiler Controls

The XL110 includes an integral modulating pump, modulating gas valve and boiler control equipment.

The XL Series documentation also describes an electronic MMI cascade controller, automatic air vent and electrical connection rail. These components form part of the boiler’s designed equipment arrangement and help support integration into a properly engineered heating system.

The complete installation must still be designed to meet the building’s hydraulic, gas-supply, electrical and control requirements.

Cascade Systems for Large Buildings

The ATAG XL Commercial range supports modular cascade arrangements, allowing multiple boilers to be combined when a single appliance cannot meet the total heating demand.

ATAG documents cascade systems of up to eight XL boilers, with wall-mounted or free-standing configurations available for suitable installations.

A correctly designed cascade can provide higher combined output and allow heating capacity to be distributed across multiple boilers. The actual installation requires suitable hydraulic separation, gas supply, flue arrangements and control coordination.

A cascade configuration does not mean multiple boilers are included in the price of a single XL110 unit. Confirm whether you are purchasing an individual boiler, connection equipment or a complete plant-room package.

Low-Velocity Header Requirement

A correctly sized low-velocity header is required for a single ATAG XL boiler or an XL cascade installation, according to the manufacturer’s installation instructions.

The header must be selected according to the system’s intended demand and hydraulic design. It should not be treated as an optional accessory where the manufacturer requires it.

Before ordering, confirm the correct header capacity, connection arrangement, pipework sizing and any compatible connection sets with the heating-system designer.

Commercial and Industrial Heating Applications

The ATAG XL110 can be considered for suitably designed heating installations such as:

  • Large commercial buildings
  • Hotels and hospitality properties
  • Schools and educational facilities
  • Offices and business premises
  • Warehouses
  • Industrial buildings
  • Multi-unit residential developments
  • Commercial plant rooms
  • Large central-heating systems
  • Multiple-boiler cascade installations

The boiler must be selected according to the building’s calculated heat demand, design temperatures, available gas supply, hydraulic arrangement and operating requirements.

Flue and Gas Supply Requirements

The ATAG XL Series documentation covers approved flue and combustion-air arrangements for suitable installations. The correct configuration depends on the building layout, terminal position, number of boilers and manufacturer’s permitted flue system.

The XL110 technical manual includes natural-gas and propane technical information for the XL range. However, fuel suitability must be verified against the exact boiler’s data plate and configuration; do not assume every supplied unit is ready to operate on both fuels.

Before purchase, confirm:

  • Approved fuel and gas category
  • Required gas pressure and supply capacity
  • Approved flue configuration
  • Condensate drainage
  • Low-velocity header capacity
  • Pipework and hydraulic design
  • Cascade control and electrical requirements
  • Installation and servicing access
  • Certification and local installation requirements

Technical Specifications

Brand: ATAG
Product range: XL Commercial
Model: XL110
Appliance type: Condensing commercial central-heating boiler
Nominal gross heat input: 107.9kW
Nominal net heat input: 97.3kW
Useful output at 80°C/60°C: 95kW
Useful output at 50°C/30°C: 102.3kW
Modulating output at 80°C/60°C: 14.8–95kW
Modulating output at 50°C/30°C: 16.8–102.3kW
Efficiency at 80°C/60°C: Approximately 97.6%, net calorific-value basis
Efficiency at 50°C/30°C: Approximately 110.3%, net calorific-value basis
Seasonal space-heating energy class: A, according to the cited technical documentation
Heat exchanger: Stainless-steel configuration
Circulation pump: Integral modulating pump
Controller: Integral boiler controller; cascade controller for appropriate arrangements
Automatic air vent: Integral
Electrical supply: 230V / 50Hz
Maximum electrical consumption: Approximately 250W
Part-load electrical consumption: Approximately 86W
Standby consumption: Approximately 3.7W
Water content: Approximately 12 litres
Maximum flow temperature: 85°C
Permitted system pressure: 0.7–4 bar, according to the cited technical table
Empty weight: Approximately 83kg
Dimensions: Approximately 1065mm high × 660mm wide × 460mm deep
Installation options: Wall-mounted or free-standing cascade arrangements
Hydraulic requirement: Correctly sized low-velocity header required

These specifications follow the ATAG XL Series technical documentation. Confirm the appliance data plate and current manufacturer’s instructions for the exact version supplied.

Installation and Safety

The ATAG XL110 is commercial-scale gas-heating equipment. It must be specified, installed, commissioned and maintained by appropriately qualified professionals in accordance with the manufacturer’s instructions and applicable local regulations.

Before ordering, confirm:

  • The building’s calculated heating demand
  • Approved gas category and supply pressure
  • Required low-velocity header
  • Pipework and hydraulic arrangements
  • Flue route and terminal requirements
  • Condensate disposal
  • Electrical and cascade-control requirements
  • Installation and servicing access
  • Product certification and local service support

The referenced ATAG installation manual identifies the relevant version as intended for the UK and Ireland. Before supplying it to another European market, verify the product’s certification, gas category, installation requirements and service arrangements for that destination.

Frequently Asked Questions

What is the ATAG XL110?

The ATAG XL110 is a high-output, modulating condensing gas boiler from the XL Commercial range, designed for central heating in large buildings and commercial installations.

Is the XL110 a 107.9kW useful-output boiler?

No. Its nominal gross heat input is 107.9kW. ATAG lists useful heating output of up to 95kW at 80°C/60°C or 102.3kW at 50°C/30°C.

Is the ATAG XL110 a domestic combi boiler?

No. The XL110 is a commercial central-heating boiler, not an instantaneous domestic combi boiler. Domestic hot-water production, if required, needs a separately designed compatible cylinder, heat exchanger or system arrangement.

Can the XL110 be connected to other XL boilers?

Yes. The XL Commercial range supports cascade configurations of up to eight boilers, subject to appropriate hydraulic, gas-supply, flue and control design.

Does the XL110 require a low-velocity header?

Yes. ATAG’s installation instructions require a correctly sized low-velocity header for single and cascade XL installations.

Can the XL110 be wall mounted?

ATAG documents wall-mounted and free-standing cascade arrangements. The correct installation format depends on the building, plant-room layout and system design.

What does 107.9kW mean?

It is the nominal gross heat-input rating. The useful heating output is the heat delivered to the heating circuit and varies with operating temperatures.

Is the XL110 suitable for every European country?

Not automatically. Confirm the supplied variant’s certification, gas category, pressure requirements, local installation regulations and service availability before supplying a particular destination.

Who should install an ATAG XL110?

An appropriately qualified commercial gas-heating professional should design, install, commission and maintain the boiler and its associated hydraulic, flue, gas and electrical systems.

Buy the ATAG XL110 Commercial Gas Boiler

The ATAG XL110 is an option for commercial heating projects requiring high output, modulating operation and potential integration into a cascade system. Before ordering from EuroFuelSupply, confirm the exact model, availability, required low-velocity header, flue components, included accessories, warranty terms and suitability for the destination country.

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “ATAG XL110 107.9kW Commercial Condensing Gas Boiler”

Your email address will not be published. Required fields are marked *

Wholesale Stock Available at Energy Fuel UK

Related Products

Fast Delivery Across the UK and Ireland