ATAG XL140 136.4kW Commercial Condensing Gas Boiler

€3,315.00

The ATAG XL140 Commercial Condensing Gas Boiler is a high-output, modulating central-heating boiler designed for large commercial buildings and demanding heating installations. It has a nominal gross heat input of 136.4kW and useful heating output of up to 120kW at 80°C/60°C or 130kW at 50°C/30°C. Features include an integral modulating pump, boiler controller, modulating gas valve and cascade-management capability. The XL range supports installations of up to eight boilers in a cascade arrangement. A correctly sized low-velocity header is required for single or cascade installations.

Fuel Supplier Europe2 Items sold in last 24 hours
11 People watching this product now!

ATAG XL140 136.4kW Commercial Condensing Gas Boiler

ATAG XL140 commercial boiler

The ATAG XL140 Commercial Gas Boiler is a high-output, modulating condensing boiler designed for large buildings and demanding central-heating installations. Part of the ATAG XL Commercial range, it is engineered to provide substantial heating capacity in commercial plant rooms and modular boiler systems.

The XL140 has a nominal gross heat input of 136.4kW, with useful heating output of up to 120kW at 80°C/60°C and 130kW at 50°C/30°C. These figures distinguish the gas energy entering the appliance from the useful heat delivered to the heating system.

The ATAG XL Commercial range comprises the XL70, XL110 and XL140 models. Each is designed for modulating central heating and can be installed in suitable wall-mounted or free-standing cascade configurations.

Key Features of the ATAG XL140 Boiler

  • ATAG XL140 high-output commercial gas boiler
  • 136.4kW nominal gross heat input
  • Up to 120kW useful output at 80°C/60°C
  • Up to 130kW useful output at 50°C/30°C
  • Modulating condensing central-heating technology
  • Stainless-steel heat-exchanger configuration
  • Integral modulating circulation pump
  • Modulating gas valve
  • Integral boiler control unit
  • Electronic MMI cascade controller
  • Automatic air vent
  • Built-in electrical connection rail
  • Compatible with approved room-sealed and open-flue arrangements
  • Suitable for wall-mounted or free-standing cascade layouts
  • Supports cascades of up to eight boilers with correctly designed system components
  • Designed for large commercial heating applications

The precise installation arrangement, supplied accessories, gas specification and warranty depend on the model configuration and destination market. Refer to the manufacturer’s instructions before purchase.

ATAG XL140 Heating Output

The XL140’s nominal gross heat input is 136.4kW. Its useful heating output depends on the operating temperatures of the heating circuit.

Technical rating Output
Nominal gross heat input 136.4kW
Nominal net heat input 123kW
Useful output at 80°C flow / 60°C return 120kW
Useful output at 50°C flow / 30°C return 130kW
Modulating useful output range at 80°C/60°C 17.6–120kW

These are manufacturer-published figures for the natural-gas XL140. The output available in an installation depends on system temperatures, operating conditions and correct commissioning.

The distinction is important when comparing commercial boilers: 136.4kW is the nominal gross input, not the useful heating output under every condition.

Condensing Technology

The ATAG XL140 uses condensing technology to recover heat from combustion gases. ATAG’s technical documentation publishes efficiency figures under specified operating conditions, including approximately 97.6% at 80°C/60°C and approximately 110.2% at 50°C/30°C on the net calorific-value basis.

Figures above 100% can occur when efficiency is expressed using the fuel’s lower heating value. They must not be compared directly with ratings calculated on a different calorific-value basis.

Actual performance depends on system temperatures, gas supply, installation design, controls, commissioning and maintenance. A published efficiency figure does not guarantee a particular reduction in operating costs.

Integral Modulating Pump and Boiler Controls

The ATAG XL140 incorporates a modulating circulation pump, modulating gas valve and boiler control unit.

Its electronic MMI cascade controller supports commercial boiler management, while the integral air vent and electrical connection rail form part of the manufacturer’s designed equipment arrangement.

These components help the XL140 integrate into a properly engineered central-heating installation. The complete system must still be designed to meet the building’s hydraulic, electrical, gas-supply and control requirements.

Cascade Installations for Large Buildings

One of the key applications of the ATAG XL Commercial range is a multi-boiler cascade installation.

ATAG specifies that XL boilers can be connected in cascade arrangements of up to eight boilers, with wall-mounted or free-standing layouts depending on the installation design. The manufacturer describes modular plant-room solutions with pre-built pipework and connections for suitable projects.

Cascade configurations can provide additional heating capacity by combining multiple boilers. The resulting system output depends on the selected models, design temperatures and hydraulic arrangement. The complete installation should be specified by a qualified commercial heating designer.

Low-Velocity Header Requirement

A correctly sized low-velocity header is required when installing a single ATAG XL boiler or a cascade of XL boilers, according to the manufacturer’s installation instructions.

The header must be matched to the required system demand and appropriate pipework. It should not be treated as an optional accessory where the manufacturer specifies it as an installation requirement.

Before ordering, confirm the required header capacity, hydraulic arrangement, gas-line sizing, flue design and relevant system connections with the installer.

Commercial and Industrial Heating Applications

The ATAG XL140 can be considered for suitably designed heating installations such as:

  • Large commercial buildings
  • Hotels and hospitality properties
  • Schools and educational facilities
  • Office buildings
  • Warehouses and industrial premises
  • Multi-unit residential developments
  • Large plant rooms
  • Commercial properties requiring a cascade boiler arrangement
  • Projects requiring high-output central heating

The boiler’s suitability should be assessed using the building’s calculated heat demand, design temperatures, available gas supply, hydraulic design and the required operating resilience.

Gas Supply and Flue Arrangements

The ATAG XL140 technical documentation includes natural-gas specifications and several approved flue categories. Gas category, supply pressure, flue configuration and installation requirements must be checked against the exact appliance identification plate and applicable documentation.

The manufacturer describes room-sealed, open-flue and over-pressure cascade-flue arrangements for appropriate configurations. Not every flue arrangement is suitable for every building, so the selected design must comply with the manual and local regulations.

Before purchase, confirm:

  • The permitted fuel and gas category
  • Gas pressure and supply capacity
  • Individual or collective flue arrangement
  • Required condensate drainage
  • Low-velocity header capacity
  • Pipework and hydraulic design
  • Electrical and cascade-control requirements
  • Mounting arrangement and maintenance access
  • Local certification and installation requirements

Technical Specifications

Brand: ATAG
Product range: XL Commercial
Model: XL140
Appliance type: Condensing commercial central-heating boiler
Fuel: Natural gas, according to the referenced technical specification
Nominal gross heat input: 136.4kW
Nominal net heat input: 123kW
Useful heating output at 80°C/60°C: 120kW
Useful heating output at 50°C/30°C: 130kW
Modulating output range at 80°C/60°C: 17.6–120kW
Efficiency at 80°C/60°C: Approximately 97.6% on the net calorific-value basis
Efficiency at 50°C/30°C: Approximately 110.2% on the net calorific-value basis
Circulation pump: Integral modulating pump
Controller: Integral boiler controller and MMI cascade controller
Gas valve: Modulating
Automatic air vent: Integral
Installation options: Wall-mounted or free-standing cascade configurations
Cascade capacity: Up to eight boilers, subject to system design
Hydraulic requirement: Correctly sized low-velocity header required
Domestic hot water: Requires a separately designed compatible system where domestic hot water is required

These figures follow the ATAG XL Commercial brochure and XL installation manual. Check the latest technical documentation and appliance plate for the exact version supplied.

Installation and Safety

The ATAG XL140 is commercial-scale gas equipment. It must be specified, installed, commissioned and serviced by appropriately qualified professionals in accordance with the manufacturer’s instructions and local regulations.

Before ordering, confirm:

  • The building’s calculated heating demand
  • The gas-supply design and approved gas category
  • The required low-velocity header
  • Pipework, pumping and hydraulic arrangements
  • Flue route and termination requirements
  • Condensate disposal
  • Cascade-control and electrical requirements, where applicable
  • Space for installation and servicing
  • Product certification and local service support

ATAG’s referenced XL installation manual specifically states that its instructions cover the UK and Ireland. Before selling the relevant version into another European market, verify that its gas category, certification, installation requirements and support arrangements are suitable for the destination.

Frequently Asked Questions

What is the ATAG XL140?

The ATAG XL140 is a high-output, modulating condensing gas boiler from the XL Commercial range, designed to provide central heating for large buildings and commercial installations.

Is the XL140 a 136kW output boiler?

Its nominal gross heat input is 136.4kW. ATAG specifies useful heating output of up to 120kW at 80°C/60°C or 130kW at 50°C/30°C.

Is the ATAG XL140 a combi boiler?

No. The XL140 is a commercial central-heating boiler, not an instantaneous domestic combi boiler. Where domestic hot water is required, the system designer must specify a suitable external cylinder, heat exchanger or other compatible arrangement.

Can multiple XL140 boilers be installed together?

The XL Commercial range supports cascade installations of up to eight boilers, subject to the required hydraulic, gas-supply, flue and control design.

Does the XL140 require a low-velocity header?

Yes. ATAG’s installation instructions require a correctly sized low-velocity header for single and cascade XL installations.

Can the XL140 be wall mounted?

ATAG documents wall-mounted and free-standing cascade arrangements. The appropriate format depends on the plant-room layout and installation design.

What is the difference between heat input and useful output?

Heat input is the gas energy supplied to the boiler. Useful heating output is the heat delivered to the heating system. The XL140’s nominal gross input is 136.4kW, while its useful output is up to 120kW at 80°C/60°C.

Is the XL140 suitable for every European country?

Not automatically. The referenced installation instructions are for the UK and Ireland. Confirm product certification, gas category, local regulations and service availability before supplying a particular destination.

Who should install an ATAG XL140?

An appropriately qualified commercial gas-heating professional should design, install, commission and maintain the boiler and its associated hydraulic, flue, electrical and gas-supply systems.

Buy the ATAG XL140 Commercial Gas Boiler

The ATAG XL140 is an option for commercial heating projects requiring high output, modulating operation and possible integration into a cascade system. Before ordering from EuroFuelSupply, confirm the precise model, product availability, required header, flue equipment, included accessories, warranty conditions and suitability for the installation country.

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “ATAG XL140 136.4kW Commercial Condensing Gas Boiler”

Your email address will not be published. Required fields are marked *

Wholesale Stock Available at Energy Fuel UK

Related Products