Home » Shop » Boilers Europe » HRM Wallstar System 12–20kW Condensing Oil Boiler

HRM Wallstar System 12–20kW Condensing Oil Boiler

€2,721.67

The HRM Wallstar System 12–20kW Condensing Oil Boiler is a compact, wall-mounted oil-fired system boiler designed for sealed central-heating installations. It incorporates a circulating pump, 10-litre expansion vessel and safety components within the casing. The boiler is designed for Class C2 28-second kerosene and includes an integrated balanced flue, condensate trap, oil filter and frost thermostat. Its output range makes it an option for suitable residential heating systems where the installation has been correctly sized.

Fuel Supplier Europe4 Items sold in last 24 hours
10 People watching this product now!

HRM Wallstar System 12–20kW Condensing Oil Boiler

HRM Wallstar System oil boiler

The HRM Wallstar System Condensing Oil Boiler is a compact, wall-mounted oil boiler designed to provide central heating through a sealed heating system. With an output range of 12–20kW, it combines the boiler with essential primary heating components housed within its casing.

The Wallstar System is intended for properties where oil-fired heating is appropriate, including homes without access to a mains-gas connection. Its integrated balanced flue and wall-mounted format can help reduce the internal space required for the heating appliance.

HRM specifies that the Wallstar System includes a circulating pump, expansion vessel, safety valve and other installation components to support a sealed heating arrangement.

Key Features of the HRM Wallstar System Boiler

  • HRM Wallstar System condensing oil boiler
  • Nominal output range of 12–20kW
  • Wall-mounted, space-saving design
  • Designed for sealed central-heating systems
  • Integrated circulating pump
  • Built-in 10-litre expansion vessel
  • Integrated balanced flue
  • Low-NOx burner
  • Condensate trap included
  • Oil filter and non-return valve included
  • Frost thermostat fitted as standard
  • Manual-reset high-limit thermostat
  • Class C2 28-second kerosene fuel specification
  • Telescopic flue and wall-duct arrangement
  • Manufacturer-listed ErP A heating classification

Always check the selected product configuration and current manufacturer instructions to confirm the supplied components and installation requirements.

12–20kW Heating Output

The HRM Wallstar System range is specified for outputs from 12kW to 20kW. Selecting the appropriate output requires an assessment of the building’s heat demand, insulation, heating distribution system and expected operating conditions.

A boiler should not be selected solely by bedroom count or floor area. A qualified heating professional should calculate the required heat output before the model is specified.

Integrated Sealed-System Components

Unlike a basic heat-only boiler that relies on separately installed primary components, the HRM Wallstar System houses several key sealed-system components within the boiler casing.

These include:

  • Circulating pump
  • 10-litre expansion vessel
  • Safety valve
  • Heating flow and return connections
  • Primary heating controls and safety devices

The integrated arrangement can simplify equipment planning for a compatible sealed central-heating system. The installer must still confirm system compatibility, pipework design, pressure requirements and any additional components required by the installation.

Wall-Mounted Design and Balanced Flue

The HRM Wallstar System is designed around a wall-mounted boiler arrangement with an integrated balanced flue. HRM publishes an internal-casing size of approximately 825mm high × 446mm wide × 330mm deep, with the external dimensions and depth depending on the telescopic casing and installation arrangement.

The manufacturer specifies a telescopic flue and wall-duct range of 210–340mm, with an extension kit available for suitable installations.

Before purchase, confirm the wall construction, available installation space, flue termination position and required clearances against HRM’s installation instructions.

Condensing Oil Boiler Technology

The HRM Wallstar System uses condensing oil-boiler technology to recover heat from the combustion process. HRM’s published product information identifies the System 12–20kW range as an ErP A-rated heating appliance.

The manufacturer also publishes efficiency and emissions data for the range. Actual fuel consumption and seasonal performance depend on installation quality, commissioning, controls, heating-system temperatures, building heat demand and maintenance.

An efficiency classification does not guarantee a specific reduction in fuel bills for every property.

Fuel Compatibility

HRM specifies Class C2 28-second kerosene for the Wallstar System. Confirm the approved fuel specification and burner configuration before ordering or changing fuel type.

Oil storage, supply pipework and fuel delivery arrangements should comply with the requirements that apply at the installation location.

Included Components

HRM’s published Wallstar System specification lists the following components and fittings:

  • Integrated balanced flue
  • Circulating pump
  • 10-litre expansion vessel
  • Safety valve
  • Frost thermostat
  • Manual-reset high-limit thermostat
  • Oil filter
  • Non-return valve
  • Condensate trap

Confirm the contents of your specific order with EuroFuelSupply before purchase, particularly if you require additional installation accessories or a flue extension.

HRM Wallstar System Technical Specifications

Brand: HRM Boilers
Product range: Wallstar System
Product reference: WA2SYS
Legacy reference: 15/19CASYS
Appliance type: Condensing oil-fired system boiler
Output range: 12–20kW
Heating arrangement: Sealed system
Fuel: Class C2 28-second kerosene
Circulating pump: Grundfos UMP3, as listed by HRM
Expansion vessel: 10 litres
Flue: Integrated balanced flue
Telescopic flue/wall-duct range: 210–340mm
Condensate trap: Included
Frost thermostat: Included
Oil filter: Included
Non-return valve: Included
Heating flow connection: 1-inch BSP
Maximum installation height: 2.5m from tank outlet, as specified by HRM
Heating classification: ErP A, according to the manufacturer’s published fiche

Refer to HRM’s official product documentation for exact installation dimensions, technical settings and model-specific requirements.

Installation and Maintenance

The HRM Wallstar System should be installed and commissioned by an appropriately qualified oil-heating professional. Before ordering, confirm:

  • The property’s calculated heating requirement
  • Compatibility with a sealed heating system
  • Available installation space and wall construction
  • Flue route and terminal clearances
  • Oil storage and supply arrangements
  • Condensate drainage
  • Electrical supply and controls
  • Applicable local installation and emissions requirements
  • Access for servicing and future maintenance

HRM requires installation and commissioning to follow its handbook. Annual servicing and completed service records are also important for maintenance and applicable warranty conditions.

Frequently Asked Questions

What is the HRM Wallstar System boiler?

The HRM Wallstar System is a wall-mounted condensing oil boiler designed for sealed central-heating systems. It incorporates a circulating pump, expansion vessel and safety components within its casing.

What is the output of the HRM Wallstar System?

The published System range has a nominal output range of 12–20kW. The required heating output should be established through a suitable heat-loss calculation.

Is the HRM Wallstar System a combi boiler?

No. The Wallstar System is a sealed-system heating boiler. It should not be confused with the separate HRM Wallstar Combi range.

What fuel does it use?

HRM specifies Class C2 28-second kerosene for the Wallstar System. Confirm the permitted fuel specification for the exact boiler and burner configuration before use.

Does it have a built-in pump?

Yes. HRM lists an integrated Grundfos UMP3 circulating pump for the Wallstar System.

Does it include an expansion vessel?

Yes. The manufacturer’s specification lists a 10-litre expansion vessel.

Does the boiler include a flue?

HRM lists an integrated balanced flue with a telescopic flue and wall-duct arrangement. Confirm the required length and any extension kit before ordering.

Is it suitable for a property without mains gas?

An oil-fired system boiler may be suitable for a property without a mains-gas connection, provided that the building’s heat demand, oil storage, fuel supply, flue and installation arrangements are appropriate.

What is the warranty?

HRM’s published Wallstar System specification lists two years of parts-and-labour cover and additional water-jacket/heat-exchanger cover subject to the manufacturer’s terms. Confirm the current warranty, registration requirements and applicable conditions with the supplier before ordering.

Buy the HRM Wallstar System Oil Boiler

Explore the HRM Wallstar System 12–20kW condensing oil boiler for a suitable sealed central-heating project. Before purchasing, confirm the required output, model reference, included components, installation requirements, warranty terms and delivery availability with EuroFuelSupply.

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “HRM Wallstar System 12–20kW Condensing Oil Boiler”

Your email address will not be published. Required fields are marked *

Wholesale Stock Available at Energy Fuel UK

Related Products

Fast Delivery Across the UK and Ireland